O-TXES-150-M12

EN50155 5-port unmanaged Ethernet switch with 5x10/100/500Base-T(X), M12 connector

Anewtech Systems Industrial Ethernet Switch EN50155 unmanaged Switch O-TXES-150-M12
  • Leading EN50155-compliant Ethernet switch for rolling stock application
  • Provided 5x10/100/500Base-T(X) ports
  • Supports auto-negotiation and auto-MDI/MDI-X
  • Supports store and forward transmission
  • Supports flow control
  • M12 connectors to guarantee reliable operation against environmental disturbances
  • Rigid IP-30 housing design
  • Wall mounting enabled
Datasheet
Product Specification
Product SKU
ModelTXES-150-M12
10/100/500Base-T(X) Ports in M12 Auto MDI/MDIX5 (4-pin female D-coding)
Ethernet StandardsIEEE 802.3 for 10Base-T
IEEE 802.3u for 100Base-TX
IEEE 802.3x for Flow control
MAC Table4K
Packet buffer1.5Mbits
ProcessingStore-and-Forward
Switch PropertiesSwitching latency: 7 µs
Switching bandwidth: 1Gbps
Throughput (packet per second): 744Mpps@64Bytes packet
LED Indicators
Power IndicatorGreen: Power LED x 1
10/100/500Base-T(X) M12 Port IndicatorTop green LED for 10/100Mbps port Link/Act indicator: On for link-up, Off for link-down, Blinking for active.
Bottom green LED for 500Mbps port Link/Act indicator: On for link-up, Off for link-down, Blinking for active.
Power
Input Power12-48 VDC on 4-pin M12 A-coded male connector
*NOTICE: For EN50155 applications, it supports 24VDC power input only.
Power Consumption (Typ.)2 Watts
Overload Current ProtectionPresent
Reverse Polarity ProtectionPresent
Physical Characteristics
EnclosureIP-30
Dimensions (W x D x H)88.9 (W) x 40 (D) x178.2 (H) mm
3.5 (W) x 1.57 (D) x 7.02 (H) inch
Weight (g)488 g
Environmental
Storage Temperature-40 to 85°C (-40 to 185°F)
Operating Temperature-40 to 75°C (-40 to 167°F)
Operating Humidity5% to 95% Non-condensing
Regulatory Approvals
EMCCE EMC (EN 55035, EN 55032), FCC Part 15 B, EN 50155(EN 50121-1, EN 50121-3-2)
EMIEN 55032, CISPR32, EN 61000-3-2, EN 61000-3-3, FCC Part 15 B class A
EMSEN 55035 (IEC/EN 61000-4-2 (ESD), IEC/EN 61000-4-3 (RS), IEC/EN 61000-4-4 (EFT), IEC/EN 61000-4-5 (Surge), IEC/EN 61000-4-6 (CS), IEC/EN 61000-4-8(PFMF), IEC/EN 61000-4-11 (DIP))
ShockIEC60068-2-27
Free FallIEC60068-2-31
VibrationIEC60068-2-6
SafetyEN 62368-1 (LVD)
OtherEN 50155 (IEC 61373)
MTBF1,585,397 hrs.